Passive Fire Protection Hyderabad | Simfy Firesys
A reinforced slab going up on a Hyderabad site — every service that crosses it will leave a hole
Passive fire protection · Hyderabad & South India

We seal the holes
fire travels through.

Every cable, pipe and duct that crosses a wall leaves a hole behind it. We close those holes the way the system was tested — in buildings that stay open while we work.

Working across South IndiaTelangana · Andhra Pradesh · Karnataka · Tamil Nadu · Kerala · PuducherrySee cities →
34+Clients served
100%Passive fire only
NBC IVOn every project
48hOn-site response
Fire-rated doors and intumescent seals in a Hyderabad building
A compartment, doing its jobRated doors, sealed frames, sealed walls. Every boundary has to hold — the door, and everything that passes through the wall beside it.
UL
UL Listed
Armacell fire stop systems
CBRI
CBRI Certified
Ameetuff mortar & coatings
NBC
IV
NBC Part-IV
Documented to the standard
✓
Photographed
Before, during and after
The thing nobody looks at

How a small fire reaches
the eleventh floor.

You do not need to be an engineer to see it. A shaft runs the full height of the building. If it is open at each floor, hot smoke goes straight up it. Two pictures explain the whole trade.

OPEN SHAFT Fire keeps climbing
Floor 12
Floor 11
Floor 10
Fire starts here

A cable shaft that is not sealed is a chimney. Smoke and heat reach the floors above in minutes, long before the flames do. People three floors up are in trouble and they never saw a fire.

SEALED SHAFT Fire stays on one floor
Floor 12
Floor 11
Floor 10
Fire starts here

Seal the shaft at every floor and the fire is boxed in. Everyone above gets the time the stairwell was designed to give them. That is the whole of it, and it is all done before handover.

Fire and smoke Fire stop mortar seal Cable / pipe shaft
How we work

Shaft closing,
step by step.

Skip the preparation and the seal looks finished but holds nothing. Here is the order we follow every time. Tap any photo to see it full size — these are our own site pictures.

Independent assessment

Know where your building stands.
Before a regulator does.

Most buildings in India pass the active fire inspection and quietly fail the passive one. We walk the building, photograph what we find, and hand you a list in the order it should be fixed.

  • Every shaft and penetration checked against a tested system
  • Coating thickness and condition on structural steel
  • Joints, wall-floor junctions and door seals
  • One summary mapped to NBC Part-IV
From ₹49,999

Per building · report in 5 working days · the fee is adjusted against the remedial work if you appoint us.

Engineer checking a fire system panel during a passive fire audit
5 daysFrom site walk to a prioritised, photographed gap report.
How we work

The building does not
have to stop.

This is the part most people assume is impossible, and it is the reason most passive fire work never gets done. The building is finished. It is occupied. Nobody wants to shut a floor to fix something they cannot see.

You do not have to. Passive fire work happens in the riser, above the ceiling and around the door frame — all places we can reach in the hours you are willing to give us. We have done it in occupied wards, trading hotels, live server rooms and offices full of staff, and on sites where three other trades were still working.

01
A building that is already finishedHandover is done, people have moved in, the ceilings are closed. We open the minimum, work the hours you give us, and put it back. Most of our work is in buildings that were signed off years ago.
02
A building that is runningA ward taking patients, a floor full of staff, a hotel selling rooms, a hall full of live racks. We take one riser, one corridor, one row at a time. Nothing closes.
03
A building where other trades are still workingWe sequence around them instead of stopping them. Our work needs the services finished and the ceiling still open — a narrow window. We plan for it rather than demanding it.
04
And we leave it the way we found itScreened working face, no dust carried into occupied areas, low-odour products near people, and the area cleaned at the end of every shift. Nobody should be able to tell we were there.
Our clients

Who we have worked for.

Developers, facility teams and contractors across Hyderabad and South India — on sites where the passive fire package had to be signed off before handover.

Where we work

Based in Hyderabad.
Working across South India.

Our team and our store are in Madhapur, Hyderabad. From there we travel — and for anything outside the city we plan the work in blocks so the mobilisation is worth the journey, for you and for us. No local offices, no local stock. We say that plainly rather than claiming branches we do not have.

TelanganaHyderabad · Secunderabad · Warangal · Karimnagar · Nizamabad · Khammam
Andhra PradeshVisakhapatnam · Vijayawada · Guntur · Tirupati · Nellore · Kakinada · Rajahmundry · Kurnool
KarnatakaBengaluru · Mysuru · Mangaluru · Hubballi–Dharwad · Belagavi · Kalaburagi
Tamil NaduChennai · Coimbatore · Madurai · Tiruchirappalli · Salem · Hosur · Tirunelveli
KeralaKochi · Thiruvananthapuram · Kozhikode · Thrissur · Kollam
PuducherryPuducherry · Karaikal

Working outside South India? Call and we will tell you honestly whether we can staff it properly, or whether you are better served by someone closer.

FAQ

Questions people actually ask

?
What is passive fire protection?Active fire protection fights the fire — alarms, sprinklers, extinguishers. Passive fire protection holds the fire in one place so it cannot spread. It is built into the walls, floors, shafts and joints, and it needs no power, no water and nobody to switch it on.
?
Why do buildings pass the fire inspection and still fail a passive check?Inspections usually look at what is easy to see and test — pumps, hydrants, alarms, extinguishers. The passive side is hidden above ceilings and inside shafts. A building can have perfect sprinklers and still have forty open cable holes that nobody has looked at since the MEP team last pulled a cable through.
?
How long does a passive fire audit take?We walk the building, photograph every issue and give you a prioritised gap report in 5 working days. Pricing starts at ₹49,999 per building. If you appoint us for the remedial work, the audit fee is adjusted against it.
?
Do you work in an occupied hospital or office?Yes. Most of our work is in buildings that cannot shut down. We sequence floor by floor, work in the windows you give us, and keep the site clean behind us. Tell us the constraint first and we will plan around it rather than discover it on day one.
?
What do we get at the end of the project?A location-by-location record: what the opening was, which tested system was used, the product details, and before-during-after photographs. That record is what your FM team, your insurer and the next contractor will need, because once the ceiling goes back nobody can see the work.
?
Is Simfy Firesys the right fit for a small project?Not always, and we will say so. If you have a handful of penetrations on one floor, a full audit is overkill — call us and we will tell you what to check yourself. We are set up for buildings with many floors, many services and a compliance deadline.

Not sure your building would pass?

One walk-through tells you exactly where you stand — with photographs, so nobody has to take anyone's word for it.

Get in touch

Tell us about the building.

Send the building type, how many floors, and what is worrying you. We will tell you honestly whether it needs a full audit or just a look at two floors.

Office
#105, Hy-End Homes, Madhapur
Hi Tech City, Hyderabad — 500 033

Straight to our passive fire team. We reply within one working day.